Originally Posted by
steveo
that's a weird one.
i think the ADX is whacked out or something, i glanced at it just now, and the error codes are all over the place. system voltage high should be an error#43 and egr should be errors 27 and 32.
honestly i never use the ADX as i have my own datalogging stuff, but i've been meaning to work it over, im just not motivated.
thing is, in that ADX, some of the errors are taken from message 0 and some are from message 2, which is... totally unnecessary.
message 0 on EE contains ALL the relavent error bits AND the data in one packet, so it's just wasting throughput. message 2 on EE is an error code only message for "dumb" error code scanners that just want the codes. it's basically cutting the available throughput for real data, since all the relavent errors are also in message 0 anyway.
either way, dont worry about that code, it's probably bunk. bit zero, byte 0x07 is the proper error for system voltage high, and that'd be error 53.