Quote Originally Posted by Fast355 View Post
It would help alot if you posted your .BIN file and the actual initial timing value you are running with the EST connector disconnected. Also post the datalog definition file you are running. It may be a problem between the .XDF you are using and the .ADX file.

For example if you have the initial timing set at 10* BTDC, have the .BIN file set at 0* your crank timing will read 10* higher with the timing light than the Tunerpro Datalog. If you have both the initial timing set at 10*, you .bin set at 10* and your .ADX has no compensation it would also read off. Post what you are using and maybe I can help shine some light on it.

Also just FYI, running lean will likely hurt your emissions. Your best bet is to keep it in the 14.2-14.7 range and pull about 6-8* of timing out of the test area. When you run it lean your mixture will not fully combust despite raised combustion temperatures and you will have a spike of unburned Hydrocarbons (HC) and Nitrogen Oxides.

Back when my old 83 G20 van still had the original quadrajet fed 305 in it, I used to block off the vacuum advance with a BB prior to the yearly smog test. It would easily pass with the timing retarded and almost always failed with the timing at factory spec.
Also, using binary for TBI 350 Vortec. If you can shed some light on the situation and provide suggestions, that would be greatly appreciated.